help-circle
  • I know I’m not answering your question, but for what it’s worth, I’ve run TrueNAS Scale and HAOS as VM’s on Proxmox for years without issue. I prefer to let my storage be storage and run a dedicated hypervisor.

    If you’re connecting drives to TrueNAS via a HBA card then virtualising TrueNAS in Proxmox is straightforward, just pass the whole card through to the VM and TrueNAS is none the wiser. The added overhead for Proxmox is (almost) negligible.

    Spin up a dedicated VM for HAOS, or whatever flavour OS you like and use docker.




  • You mention frigate specifically. Were you running this on the system when the drive failed, or is this a future endeavour?

    I bring this up because I also use frigate, and for some time I was running with a misconfigured docker compose that drove my SSD wearout to 40% in a matter of months.

    Make sure that the tmpfs is configured per the frigate documentation and example config. If misconfigured like mine was, all of that IO is on disk. I believe the ramdisk is used for temp storage of camera streams, until an event occurs and the corresponding clip is committed to disk.

    Good luck!


  • Pulling around 200W on average.

    • 100W for the server. Xeon E3-1231v3 with 8 spinning disks + HBA, couple of sata SSD’s
    • ~80W for the unifi PoE 48 Pro switch. Most of this is PoE power for half a dozen cameras, downstream switches and AP’s, and a couple of raspberry pi’s
    • ~20W for protectli vault running Opnsense
    • Total usage measured via Eaton UPS
    • Subsidised during the day with solar power (Enphase)
    • Tracked in home assistant


  • thumdinger@lemmy.worldtoSelfhosted@lemmy.worldHelp me decide?!
    link
    fedilink
    English
    arrow-up
    2
    ·
    edit-2
    1 year ago

    For storage redundancy RAID 5 is not recommended, particularly as you get to high capacity drives (think >8TB). I think the rating to consider is URE (unrecoverable read error, usually 1 in 10^14 bits read).

    Once a drive inevitably fails and you are forced to resilver the array to avoid data loss. During the resilver the healthy disks are running at 100%, reading every bit of data they have to complete the parity calculation and determine what data is missing. The chances of encountering a URE on another drive is a near certainty at high capacities as the total number of bits read exceeds the URE rating. As result the resilver would fail and the array would be lost.

    RAID 6 as a minimum (2 drive redundancy), although a popular option now (and the layout I use) is mirrored vdevs.

    Edit: Consider TrueNAS for NAS software. I have been using it for 10 years and it is absolutely rock solid. 25TB usable storage across 4x mirrored vdevs. I run it as a VM inside Proxmox with 4 logical cores on a 10 year old Xeon with 16GB RAM for the VM (I run ECC as was recommended at the time, but whether it’s still considered necessary I’m not certain).

    I would also recommend getting an LSI HBA (host bus adapter) like the 9207-8i flashed to IT mode (it must not be in raid mode, let TrueNAS manage the disks directly). This simplifies passing through all the disks to a VM.




  • I use the Amplipi from Micro-Nova for whole-home audio and I love it. It’s local, open source and has a Home Assistant integration.

    The main unit has 6 zones, but expansions units can be added. I think it supports up to 4 simultaneous streams. We use 2x AirPlay streams, and a turn table connected via RCA, but many other options are supported. They detail it all on their website and GitHub repo.